EVAPORATING COOLER
The
evaporating condensers are equipment for condensation, subcooling of refrigerant
gases and for cooling of liquids or gases such as water or air.
Name : CE
A18 F
CE: Evaporating Cooler
A: Type of serpentine
18: Amount of serpentines
F: Freon
N: Amonia
DESIGN AND
MANUFACTURING
When designing the condenser the focus has been on a combination of low
operating weight and high rigidity. Condensers are built in heavy steel
sheets with antirusting treatment and galvanized steel sheets.
The condenser has two parts: one where the serpentine, nozzles for water
distribution and fluid collectors are and another for tank and water pump.
The whole structure is compact, making it easy to install and highly effective.
All parts are easy to maintain, not being necessary desassemble any door,
lid or structure to access to them. The water tank has the dimensions
to store the volume required by the equipment. No extra tank is necessary.
The serpentine is make of steel pipe of 50 kg/cm2 of resistance, bent
in cold and later galvanized by bathing them in hot zinc, tested to 25
kg/cm2.
The serpentines can be divided into one, two or more parts for different
condensing circuits, with one part for water cooling of compressors, eliminating
formation of incrustations in water system. Where room temperature is
below water freezing temperature, it is imposible to add antifreezing
liquids into the system such as glicoles.
The water distribution system has no-plugging nozzles on zinc antirusting
collectors, distributing the amount of water required to keep the therrmic
exchange surface constantly wet. The water distribution system does not
need any adjustment. The section of drop eliminators is built rigidly
in galvanized steel sheets entirely. Its location no the upper part of
the equipment allows easy reach to nozzle
The forcers are axial type, assembled on the water deposit, easy to reach
on floor level. The electric motors are 100% pretected against water or
dust.
The water tank in heavy steel sheet is rust protected with zinc. The water
level is constant by a high pressure floating valve. A suction filter
makes it impossible for particles to be impulsed by the pump towards the
nozzles. There is emptying conection, continum water purge and purge by
stopping the equipment.
The water pump is monoblock type, 100% shielded, joined to the water trank
by a pass valve.
TECHNICAL
SPECIFICATIONS

|
MOD.
|
CAPACITY
|
DIMENSIONS ( mm )
|
FORCERS
|
WATER PUMP
|
VOLUMEN
|
WEIGHT
|
|
|
|
KW
|
Kcal/h
x1000
|
A
|
B
|
C
|
Cant.
|
CV
|
Cant.
|
CV
|
metros3
|
Kg.
|
|
CEA
22
|
91.9
|
79
|
2400
|
730
|
2600
|
2
|
1
|
1
|
1
|
4.2
|
1.000
|
|
CEA
26
|
108.1
|
93
|
2400
|
860
|
2600
|
2
|
1.5
|
1
|
1
|
5
|
1.200
|
|
CEA
32
|
125.6
|
108
|
2400
|
980
|
2600
|
2
|
1.5
|
1
|
1
|
5.5
|
1.300
|
|
CEA
38
|
151.2
|
130
|
2400
|
1200
|
2600
|
2
|
2
|
1
|
1.5
|
6.2
|
1.500
|
|
CEA
46
|
182.6
|
157
|
2400
|
1400
|
2600
|
2
|
2
|
1
|
1.5
|
8.2
|
1.800
|
|
CEA
54
|
212.8
|
183
|
2400
|
1700
|
2600
|
2
|
2
|
1
|
1.5
|
11.5
|
2.900
|
|
CEB
39
|
290
|
250
|
3500
|
1300
|
2900
|
3
|
2
|
1
|
2
|
13.2
|
3.200
|
|
CEB 48
|
357
|
307
|
3500
|
1600
|
2900
|
3
|
3
|
1
|
3
|
16.3
|
3.700
|
|
CEB 56
|
418.6
|
360
|
3500
|
1850
|
2900
|
3
|
3
|
1
|
3
|
18.8
|
4.000
|
|
CEB 65
|
483.7
|
416
|
3500
|
2150
|
2900
|
3
|
3
|
1
|
3
|
22
|
4.300
|
|
CEC 52
|
531.4
|
457
|
4600
|
1750
|
3100
|
4
|
3
|
1
|
4
|
25
|
4.800
|
|
CEC 56
|
560.5
|
482
|
4600
|
1850
|
3100
|
4
|
3
|
1
|
4
|
26.5
|
5.000
|
|
CEC 60
|
600
|
516
|
4600
|
2000
|
3100
|
4
|
3
|
1
|
4
|
28.7
|
5.300
|
|
CEC 65
|
650
|
559
|
4600
|
2150
|
3100
|
4
|
4
|
1
|
7.5
|
31
|
5.600
|
|
CEC 70
|
700
|
602
|
4600
|
2300
|
3100
|
4
|
4
|
1
|
7.5
|
33
|
5.900
|
|
CEC 75
|
750
|
645
|
4600
|
2500
|
3100
|
4
|
4
|
1
|
7.5
|
36
|
6.200
|
|
CEC 84
|
839.5
|
722
|
4600
|
2750
|
3100
|
4
|
5.5
|
1
|
10
|
40
|
7.300
|
|
CEC 90
|
901.2
|
775
|
4600
|
3000
|
3100
|
4
|
5.5
|
1
|
10
|
43
|
9.000
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
T.cond.=
+ 35ºC. - T.bh= + 24ºC.
Products
|
 |